Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
E000 WS IOP or IOA error during working operation AJLYD01
FI00610
F000 WS IOP or IOA operating system program error AJLYD01
FI00719
Table 2. Failing Items Details
Failing Item Description Document Description
AJDG301 OS/400 licensed program Service Functions; APAR or LICTR
AJDGP01 LIC - Input/Output Processor Licensed Internal
Code
Service Functions; APAR or LICTR
AJLYD01 Work Station IOP or IOA system Licensed
Internal Code
Service Functions; APAR or LICTR
CAUPDT Device Licensed Internal Code change Communications Configuration
GAU7777 Electrical interference
GAU8888 Other work station on port is failing
GAU9999 Error occurred with pass-through command
GAUBBBB Too many work stations are active on the
workstation IOP
GAUDMCC Device Licensed Internal Code change
GAUEEEE Active device turned off
MAUFFFF Magnetic stripe Refer to I/O device service information
UAUFF00 User suspected problem.
(B075) Workstation Adapter Console Reference Codes
The workstation adapter console detected a failure.
1. Look at characters 5 through 8 of the top 16 character line of function 11 (4
rightmost characters of word 1). These 4 characters are the unit reference code.
2. Find the unit reference code in the following table.
For more on the Failing Item column entries, see Table 2. Workstation Adapter
Console Failing Items Details, which follows the reference code table below.
Table 1. (B075) Workstation Adapter Console Reference Codes
Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
0101 WS IOP detected error when transmitting data
Perform WSAC-PIP1.
FI00601
GXC7777
FI00631
FI00730
0103 WS IOP detected parity error from device
Perform WSAC-PIP1.
FI00601
GXC7777
FI00631
FI00730
B070
220
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)

Table of Contents

Other manuals for IBM iSeries 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 800 and is the answer not in the manual?

IBM iSeries 800 Specifications

General IconGeneral
BrandIBM
ModeliSeries 800
CategoryServer
LanguageEnglish

Related product manuals