3. When this procedure instructs you to power on the system or partition, power off or power on only
the partition that reported the problem by selecting Work with system partitions under SST/DST.
Then, from the Primary partition, use HSM concurrent maintenance to power off the card positions
that you are instructed to work with. The remove and replace procedures for those positions will guide
you through the HSM concurrent maintenance functions. Use this procedure to find the correct
remove and replace procedure for each card position that you are instructed to work with.
4. Power off the system or partition.
5. Remove all of the IOAs that you marked with an ″X″ in Installed features in a PCI bridge set form. Be
sure to record the card position of each IOA so that you can reinstall it in the same position later. To
determine the remove and replace procedures for the IOAs, locate the IOA card positions in the FRU
locations and failing items table for the frame type that you recorded. FRU locations and failing items
tables are in Locations and addresses.
6. Power on the system or partition.
Does the SRC or failure that sent you to this procedure occur?
v Yes: Continue with the next step.
v No: Power off the system or partition. Go to step 12 (See page 93).
7. Perform the following:
a. Power off the system or partition.
b. Exchange the IOP that is indicated in the DSA. Be sure to record the card position of the IOPs so
that you can reinstall it in the same position later. To determine the remove and replace procedure
for the IOP, locate the IOP’s card position in the FRU locations and failing items table for the
frame type you recorded. FRU locations and failing items tables are in Locations and addresses.
c. Power on the system or partition.
Does the SRC or failure that sent you to this procedure occur?
v No: Power off the system or partition and continue with the next step.
v Yes: Go to step 18 (See page 94).
8. Install all of the IOAs that you removed in step 5 (See page 93). Be sure to install them in their
original positions.
9. Power on the system or partition.
Does the SRC or failure that sent you to this procedure occur?
v Yes: Power off the system or partition. Then, continue with the next step.
v No: Perform “Bus PIP verify - RA” on page 101.
This
ends the procedure.
10. Remove all of the IOAs that you marked with an ″X″ in Installed features in a PCI bridge set form. Be
sure to record the card position of each IOA so that you can reinstall it in the same position later.
11. Remove the IOP that you exchanged and install the original IOP in its original position.
12. Reinstall, in its original position, one of the IOA adapters that you removed.
13. Power on the system or partition.
Does the SRC or failure that sent you to this procedure occur?
v Yes: The I/O adapter card that you just installed is the failing FRU. Continue with the next step.
v No: Power off the system or partition. Repeat step 12 (See page 93) for another one of the I/O
adapter cards that you removed.
If you have reconnected all of the I/O adapters and the SRC or failure that sent you to this
procedure does not occur, the problem is intermittent.
This ends the procedure.
14.
Power off the system or partition.
15. Exchange the I/O adapter card that you last installed. Be sure to install the new I/O adapter card in
the same position.
16. Power on the system or partition.
Analyze hardware problems 93