180-901-000 Check-point Panel Test Failed
Explanation: Check-point Panel Test Failed. Operator reported incorrect display.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check the operator information panel cabling for loose or broken connections at both ends or damage to the
cable.
2. Replace the information panel cable if damage is present.
3. Run the test again.
4. Replace the operator information panel assembly.
5. Run the test again.
6. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.