- 106 -
speed-up/speed-down time and the setup speed-up/speed-down time.
There are totally four groups o speed-up/speed-down time for selection.
Group 1: F0-17 and F0-18;
Group 2: F8-03 and F8-04;
Group 3: F8-05 and F8-06;
Group 4: F8-07 and F8-08;
It can select speed-up/speed-down time via the multifunctional digital input
terminals (F4-00 to F4-08).
Group F1 Motor Parameters
Motor type
selection
Factory default
value
2
0 Common asynchronous motor
1 Variable frequency asynchronous motor
F1-00
Setup
range
2 Permanent magnetic synchronous motor
Rated power
Factory default
value
Model dependent
F1-01
Setup
range
0.4kW1000.0kW
Rated voltage
Factory default
value
Model dependent
F1-02
Setup
range
0V440V
Rated current
Factory default
value
Model dependent
F1-03
Setup
range
0.00A655.35A
Rated
Frequentcy
Factory default
value
Model dependent
F1-04
Setup
range
0.00Hz~ maximum frequency
Rated rotation
speed
Factory default
value
Model dependent
F1-05
Setup
range
0rpm30000rpm

Table of Contents

Other manuals for Inovance IS300T080-C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance IS300T080-C and is the answer not in the manual?

Inovance IS300T080-C Specifications

General IconGeneral
BrandInovance
ModelIS300T080-C
CategoryServo Drives
LanguageEnglish

Related product manuals