EasyManuals Logo

Inovance IS300T080-C User Manual

Inovance IS300T080-C
211 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #57 background imageLoading...
Page #57 background image
- 51 -
4.4 Method of Viewing Status Parameter
In stop or running status, it can display multiple status parameters.
It can select whether to display the parameter through the function
codes F7-04 (running parameter) and F7-05 (stop parameter) in
accordance with the binary bits. For the meanings of the binary bits,
refer to Chapter 6 F7-04 and F7-05 Function Codes for details.
In the
running status, five running status parameters are always displayed,
namely, setup frequency, bus voltage, output voltage , and output current, and
other sixteen parameters, namely, DI input status, DO output status, analog
input AI1 voltage, analog input Al2 voltage, analog input AI3 voltage and four
reserved parameters ,etc.They are displayed in accordance with the selection
of F7-04 (converted into decimal system). The displaying of the selected
parameters may be switched by the button sequence.
In the stop status, there are totally sixteen stop status parameters for selection,
namely, setup frequency, bus voltage, DI input status, DO output status,
analog input AI1 voltage, analog input Al2 voltage, analog input AI3 voltageor
current and five reserved parameters,They are displayed in accordance
with the selection of F7-05 (converted into decimal system).The displaying of
the selected parameters may be switched by the button sequence.
When the servo driver is restarted upon power shutdown, the displayed
parameters are the parameters selected before the power shutdown.
4.5 Password Setup
The driver provides user password protection function. When FP-00 is set to
non-zero value, it indicates the user password, and the password protection
turns valid after exiting the function code editing status. When pressing PRG
key again, “------“ will be displayed, and common menu cannot be entered until
user password is input correctly.
To cancel the password protection function, enter with password and set
FP-00 to “0”.
The user password protection for the parameter items in the shortcut men
depends on the status of F7-03, and is inenabled for the parameter values.

Table of Contents

Other manuals for Inovance IS300T080-C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance IS300T080-C and is the answer not in the manual?

Inovance IS300T080-C Specifications

General IconGeneral
BrandInovance
ModelIS300T080-C
CategoryServo Drives
LanguageEnglish

Related product manuals