- 154 -
Group FD Communication Parameters(Reserved)
Group FP User Password
user password
(Authorization for all
functions code except
FP-05)
Factory default
value
0
FP-00
Setup range 0 to 65535
Any non-zero number can be set, and then the password protection function
will be enabled.
000: Clear the previous setup user password and disable the password
protection function.
Upon setup and validation of the user password, when the user enters the
parameter setting status again, the user can view the parameters only and
cannot modify the parameter if the password is incorrect. Please remember
the setup user password correctly. If the password is set wrongly or forgotten,
please contact the manufacturer.
Parameter
initialization
Factory default
value
0
0 No operation
1
Restore the factory default setup
value
FP-01
Setup range
2 Clear the fault record
1: The driver restores all the parameters except the parameters in Group F1
to the factory default ones.
2: The driver clears the recent fault records.
3:Restore the setup function code value of the FP-04 saved.