EasyManuals Logo
Home>Inovance>Servo Drives>IS300T080-C

Inovance IS300T080-C User Manual

Inovance IS300T080-C
211 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #97 background imageLoading...
Page #97 background image
- 91 -
Select the
reverse of
feedback
speed
Factory
default value
0
0
Select the forward direction of speed
direction
A1-03
Setup
range
1
Select the reverse direction of speed
direction
Rotary
transformer
number of
pole-pairs
Factory
default value
1
A1-04
Setup
range
150
Group A2 CAN Communication Group
Baud rate
selection
Factory
default value
4
0 20k
1 50k
2 125k
3 250k
4 500k
A2-00
Setup
range
5 1M
CAN
communication
address
Factory
default value
1
A2-01
Setup
range
1255
A2-02
CAN
communication
continuous
time
Factory
default value
0.0

Table of Contents

Other manuals for Inovance IS300T080-C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance IS300T080-C and is the answer not in the manual?

Inovance IS300T080-C Specifications

General IconGeneral
BrandInovance
ModelIS300T080-C
CategoryServo Drives
LanguageEnglish

Related product manuals