Chapter 3: System functions
96 Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
5. Press the programming key sequence to activate the fob, or press Enter to
enter fob identifier and fob encryption key manually. See “Device activation
on page 97 for more information about activation.
Fob ID
> <
Fob key
> <
If the input has been already programmed, you are informed by a message and
seven beeps.
INFO
Fob exists
Next you are asked if you want to replace the programmed fob.
Replace fob?
>No<
If the fob is programmed successfully, the keypad shows an information
message and beeps once.
INFO
Fob learned
Next you are asked if you want to edit the new fob.
Edit fob?
>No<
Choose Yes and press Enter to edit fob settings.
Otherwise you are asked if you want to learn another fob.
Next fob?
>No<
Choose Yes if you need to configure more fobs. The procedure will be then
repeated.
Two-zone RF sensors
Particular RF devices, for example, door/window sensors and shock sensors,
have two inputs on-board. If both inputs are enabled in the device, during the
configuration process the system asks if two zones should be used to report
these inputs states.
Note: For two zones to be visible upon device learning process, the device must
have an appropriate configuration during the activation. See Table 19 on page 97
for more details.
1 or 2 zones
>2<

Table of Contents

Other manuals for Interlogix ATS4500A-IP-MM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ATS4500A-IP-MM and is the answer not in the manual?

Interlogix ATS4500A-IP-MM Specifications

General IconGeneral
BrandInterlogix
ModelATS4500A-IP-MM
CategorySecurity System
LanguageEnglish

Related product manuals