Chapter 8: Regulations
308 Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
Options affected by other regulations
ACPO policy
Required settings are all EN 50131 Grade 2 settings with the following
modifications:
• 4.2.n.5.1 Entry alarms, Delayed
• 8.2.4 Engineer reset, tamper enabled
• 8.7.6 Alarm confirm:
- AB mode, enabled for all relevant areas
- AB time, 30 min minimum, 60 min maximum
- EE Confirm, enabled
- TA confirm, enabled
Note: ACPO policy allows a higher level manager to become a level 3 user. Also,
level 3 user menu access may be allowed without level 2 user authorization if it is
provided by appropriate written agreement from the customer.
INCERT policy
Required settings:
• Isolate for End Users option disabled in 3.2.n.6 User group options
• Full Set/Part Set/Unset/Forced Set for Installer disabled in 3.2.n.6 User group
options
• 8.2.4 Engineer reset, tamper enabled
• 8.4.1 RTS options, all enabled except FTC, Pending Alarms, and Zone
technical alarm, that are optional
• RTS for Battery Fault enabled in 8.4.1 RTS options
• Inhibit for Battery Fault disabled in 8.4.2 Inhibit includes
• PIN length should be 6 digits minimum. See also “8.7.4 PIN length”.
SES policy
Depending on the SES default chosen, the following SES settings are required
on top of EN 50131 Grade 2 / Grade 3.
• Take care that a proper dedicated panic button is used (which cannot be
pushed by accident).
• Automatic unsetting is not allowed.