Chapter 3: System functions
68 Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
Access control
The Advisor Advanced system allows controlling user access to particular
regions using doors. There are the following types of access control functions:
Basic access control function is controlling alarm function by shunting door
contact when an authorized user badges a valid card or enters a valid PIN, or
presses request to exit button. Such access control functions are provided
using standard doors.
See “Door shunton page 69 for more information on door shunts.
See also “Doorsbelow, “Zone shunton page 53.
Advanced access control functions include anti-passback, high security
regions etc. These functions are only available while using intelligent doors,
which are controlled by door controllers (see “Door controllerbelow).
See also “Advanced access control functionson page 69.
Door controller
The advanced access control functions are handled by a door controller, which is
an expander connected to the ATS system bus.
One door controller can control up to four intelligent doors.
Currently there are the following door controllers available: ATS1250, ATS125x
(ATS1251, ATS1252, ATS1253, ATS1254).
See “Expanderson page 59 for more information on expander installation.
Doors
A door is a basic element of the access control functionality. There are two types
of doors:
Standard door: A door with a reader or a keypad assigned to each side of the
door, and a request to exit button for an exit. Unauthorised door opening
causes an intrusion alarm. See “Basic access control functionson page 69.
Intelligent door: A door, which can be used for advanced access control. Such
door has up to two readers and a region assigned to each side, entry and
exit. Such doors are controlled by door controllers. See “Advanced access
control functionson page 69.
Use menu “5 Door menuon page 196 to configure doors.
For reader, door zone and lock outputs default addressing, see “Zone, output,
and door addressingon page 31 in Chapter 2 “Installation”.

Table of Contents

Other manuals for Interlogix ATS4500A-IP-MM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ATS4500A-IP-MM and is the answer not in the manual?

Interlogix ATS4500A-IP-MM Specifications

General IconGeneral
BrandInterlogix
ModelATS4500A-IP-MM
CategorySecurity System
LanguageEnglish

Related product manuals