Parameter Min Max Default value
Angular coverage (for each sensor) 110°. 50° 110°
Safety working mode (for each detection
field of each sensor)
Both (default), Always access detection,
Always restart prevention
Both (default)
Restart timeout for each detection field 0 ms 60000 ms 10000 ms
T
OFF
100 ms 60000 ms 100 ms
Settings > Sensors
Detection field dependency Enabled, Disabled Enabled
Access sensitivity Normal, High, Very High Normal
Restart sensitivity Normal, High, Very High Normal
Anti-masking Disabled, Low, Medium, High
High
Anti-rotation around axes Disabled, Enabled Enabled
Settings > Digital Input-Output
Digital input (for each input) Stop signal, Restart signal, Muting group
“N”, Activate dynamic configuration,
Fieldbus controlled, Acquisition Trigger
Not configured
Digital output (for each output) System diagnostic signal, Muting enable
feedback signal, Fieldbus controlled,
Restart Feedback signal, Detection signal 1,
Detection signal 2, Acquisition Trigger
Not configured
OSSD Pulse width Short (300 μs), Long (2 ms) Short (300 μs)
Settings > Muting
Group for muting (for each sensor) None, Group 1, Group 2, both Group 1
Pulse width (for each Input TYPE) 0 μs (= Period and
Phase shift disabled)
200 μs
2000 μs 0 μs
Period (for each Input TYPE) 200 ms 2000 ms 200 ms
Phase shift (for each Input TYPE) 0.4 ms 1000 ms 0.4 ms
Settings > Restart parameters
Detection field 1, 2, 3, 4 Automatic, Manual, Safe manual Automatic
Settings > Multi-control unit synchronization
Control unit channel 0 3 0
Settings > Activity History
Log verbosity level 0 5 0
Settings > Network Parameters
IP Address - 192.168.0.20
Netmask - 255.255.255.0
Gateway - 192.168.0.1
TCP port for configuration 1 65534 80
Settings > Fieldbus Parameters
System configuration and status PS2v6 1 65535 145
Sensors information PS2v6 1
65535
147
Sensor 1 detection status PS2v6 1
65535
149
Sensor 2 detection status PS2v6 1
65535
151
Sensor 3 detection status PS2v6 1
65535
153
Sensor 4 detection status PS2v6 1
65535
155
Sensor 5 detection status PS2v6 1
65535
157
Sensor 6 detection status PS2v6 1
65535
159