4. Functioning principles
4.2 Detection fields
4.2.1 Introduction
The field of view of each sensor can be composed of up to two detection fields. Each of the two detection fields
have a dedicated detection signal.
WARNING! Configure the detection fields and associate them with the dual channel safety outputs
according to the risk assessment requirements.
Detection field examples
Angular coverage Detection fields
110°
50°
4.2.2 Detection field parameters
These are the programmable parameters for each sensor:
l angular coverage (50° or 110°)
These are the programmable parameters for each detection field:
l detection distance
l safety working mode (Both (default), Always access detection or Always restart prevention) (see
"Safety working modes and safety functions" on page35)