Chapter 3 Adjustment Mode
3.2.9 Adjusting Squeeze Amount of the Postsqueezing Plate
Adjust the squeeze amount of the postsqueezing plate in such a way that the gap created by the
postsqueezing plate when the postsqueezing plate moves toward the nearest position is within 5 mm ± 1
mm.
1) Touch the [UNIT TEST] in the Adjustment
Mode.
2) Select [LIFTER] and touch [EXECUTE.]
3) Check that the gap is within 5 mm ± 1 mm when the postsqueezing plate moves toward the nearest
position.
4) If the gap is not within 5 mm ± 1 mm, adjust the
gap with the screws (2) of the postsqueezing
arm on the right lateral.
5) Move the postsqueezing plate back and forth
once and check that the postsqueezing arm
does not hit the detection plate and the sensor.
Postsqueezin
l
Within 5 mm ± 1 mm
Screw
Postsqueezing
plate
Postsqueezing
arm
Detection plate and
sensor
Postsqueezing
arm
3-52