Chapter 3 Adjustment Mode
3.2.9 Adjusting Squeeze Amount of the Postsqueezing Plate
Adjust the squeeze amount of the postsqueezing plate in such a way that the gap created by the
postsqueezing plate when the postsqueezing plate moves toward the nearest position is within 5 mm ± 1
mm.
1 Touch the [UNIT TEST] in the Adjustment
Mode.
2 Select [LIFTER] and touch [EXECUTE.]
3 Check that the gap is within 5 mm ± 1 mm when the postsqueezing plate moves toward the nearest
position.
4 If the gap is not within 5 mm ± 1 mm, adjust the
gap with the screws (2) of the postsqueezing
arm on the right lateral.
5 Move the postsqueezing plate back and forth
once and check that the postsqueezing arm
does not hit the detection plate and the sensor.
Postsqueezin
g
p
l
ate
Within 5 mm ± 1 mm
Screw
Postsqueezing
plate
Postsqueezing
arm
Detection plate and
sensor
Postsqueezing
arm
3-52