Chapter 3 Adjustment Mode
3.2.10 Adjusting Discharge Pusher Standby Position
Adjust the standby position of the discharge pusher as follows:
1 Check that the standby position of the discharge pusher (from the front of the discharge pusher to the
backside of the plate) is 261 - 264 mm.
2 If the standby position is not at 261 - 264 mm, adjust the position with screws (2) on the discharge
pusher arm at the right lateral.
3 After adjustment, activate the discharge pusher and check again the distance to the standby position.
Front of the
dischar
g
e
p
usher
Backside of
the
p
late
Distance to the standby position:
261 - 264 mm
Screw
Discharge pusher arm
3-53