Chapter 3 Adjustment Mode
10) If the gap is not 1 – 3 mm, repeat the above procedure 5 through 9 to adjust height.
If the gap still does not fall in the range of 1 – 3 mm, loosen the hexagonal bolts (3) in the back to
adjust height in a similar way.
NOTE:
The check on the lift can be conducted by executing [Unit Operation] l [Lift] in the Maintenance
Adjustment Mode.
In this case, check that the top end of the lift hits on the shaft. If you hear a sound when the lift goes up,
the situation is OK.
Hexagonal bolts (3)
3-35