Basic Operation
The principle of parameter setting of Ch1 and Ch2 and Ch3 is the same, so
the description will not be repeated.
Name Description
V
in1
Indicates the start voltage input to pin 8. The
setting range is from –10 to 10.
V
in2
Indicates the end voltage input to pin 8. The
setting range is from –10 to 10, and
V
in2
>V
in1
.
V
out1
The starting value of the output voltage in
CV priority mode.
V
out2
The end value of the output voltage in CV
priority mode, and V
out2
>V
out1
.
I
out1
The starting value of the output current in
CC priority mode.
I
out2
The end value of the output current in CC
priority mode, and I
out2
>I
out1
.
CV priority
CC priority
How to Use
The following takes the CV priority mode as an example to introduce the usage
steps.