Basic Operation
The detailed parameter description is as below.
Ext-Program External analog function menu
On / Off Function switch:
On: Turns on the external analog function.
In this state, the channel parameters cannot
be set.
Off: Turns off the external analog function.
In this state, the channel parameters can be
set.
Ch1 Set the parameters of channel 1 (programmed
channel).
Mx Indicates the slope factor of channel 1.
Mb Indicates the offset of channel 1.
Ch2 Set the parameters of channel 2 (upper limit
channel).
Mx Indicates the slope factor of channel 2.
Mb Indicates the offset of channel 2.
Ch3 Set the parameters of channel 3 (lower limit
channel).
For the IT6000D series of unipolar power
supplies, the voltage/current lower limit
does not need to be specified. Therefore,
the Ch3 parameters here do not need to
be set.
Mx Indicates the slope factor of channel 3.
Mb Indicates the offset of channel 3.
CV priority: The actual output voltage Vset will be adjusted according to the
parameter setting of Ch1 and the input voltage of the corresponding pin.
And, the current upper limit Ilim will be adjusted according to the parameter
setting of Ch2 and the input voltage of the corresponding pin.
CC priority: The actual current voltage Iset will be adjusted according to the
parameter setting of Ch1 and the input voltage of the corresponding pin.
Copyright © Itech Electronic Co., Ltd.
114

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6000D Series and is the answer not in the manual?

ITech IT6000D Series Specifications

General IconGeneral
BrandITech
ModelIT6000D Series
CategoryPower Supply
LanguageEnglish

Related product manuals