System Commands
Copyright© Itech Electronic Co., Ltd. 14
Chapter3 System Commands
SYSTem:ERRor?
This command is used to read the error information.
Command syntax
SYST:ERR?
Arguments
None
Returns
<NR1>, <SRD>
SYSTem:VERSion?
This command is used to query the current SCPI version.
Command syntax
SYST:VERS?
Arguments
None
Returns
<NR2>
Example
1991.1
SYSTem:REMote
This command is used to switch to the remote control mode(PC control).
Command syntax
SYST:REM
Arguments
None
SYSTem:LOCal
This command is used to switch the instrument to local control mode
(control from panel).