Channel Combination Commands
Copyright© Itech Electronic Co., Ltd. 41
Parameter 1
CH1|CH2|CH3
Parameter 2
CH1|CH2|CH3
Optional Parameter 3
CH1|CH2|CH3
Example
INST:COM:TRA CH1,CH2,CH3
INSTrument:COMbine:TRACk none
This command is used to disable the channels synchronization state.
Command syntax
INSTrument:COMbine:TRACk none
Arguments
None
Note: Series, parallel, and synchronous cannot be directly switched to
each other. You need to remove the current association before
configuring.
INSTrument:COUPle[:TRIGger]
This command is prepared for the trigger command *TRG to specify which
channels are affected by *TRG. When this command does not specify a
channel, the *TRG command only affects the current channel. Each channel is
separated by a comma.
Arguments
CH1|CH2|CH3
Query syntax
INSTrument:COUPle[:TRIGger]?
Example
INSTrument:COUPle[:TRIGger] CH1, CH2