J-100
14.3 Panel Displays SN--1
Open sensor (heater is disabled) or shorted sensor (spa is
deactivated). The high-limit temperature sensor is not functioning.
Contact your authorized Jacuzzi dealer or qualified service technician.
The display will alternate between “SN--1”, scrolling message “HI-LIMIT
SENSOR ERROR” and the current water temperature.
14.4 Panel Displays SN--2
Open or shorted sensor (heater disabled). The temperature
sensor is not functioning. Contact your authorized Jacuzzi dealer or
qualied service technician. The display will alternate between “SN--2”,
scrolling message “WATER SENSOR ERROR” and the current water
temperature.
14.5 Panel Displays Change CLEARRAY Bulb
The display will alternate between the current temperature reading and the
scrolling message “CHANGE CLEARRAY BULB” as long as the error
exists. The countdown timer for the UV bulb needs to be turned off.
1. Press until you get to the UV Menu. The display will scroll
CLEARRAY BULB.” After the second scroll, if no action is taken,
the system will revert back to the Main Menu.
2. Press or to prepare the system for changes. Continually
press until you see “OFF” on the display.
14.6 Panel Displays Change Filter
The lter change timer has expired. The spa lters need to be cleaned
or replaced. The display will alternate between the current temperature
reading and the scrolling message “CHANGE FILTER” as long as the
error exists. The countdown timer for the Change Filter feature needs to
be reset (page 36). New lters can be purchased from a local Jacuzzi
dealer.
14.7 Panel Displays Change Water
The water refresh timer has expired. The spa needs to be drained and
relled. The display will alternate between the current temperature
reading and the scrolling message “CHANGE WATER” as long as the
error exists. The countdown timer for the Change Water feature needs to
be reset (page 31).
14.8 Panel Displays FL--1
An “FL--1” display means the ow switch is malfunctioning
open, the lter cartridge is excessively dirty or an “air lock”
condition has occurred at the pump intake. The spa heater will deactivate
and jets pump #1 may also deactivate. Contact your authorized Jacuzzi
dealer or qualified service technician. The display will alternate between
“FL--1,” scrolling message “FLOW ERROR OPEN” and the current
water temperature.