Page #54 background image
Operation
Instruments
47 9831/0650-3 47
Stopping The Engine
Select STOP/RESET mode. The generator is stopped.
Figure 34.
B
B Stop/reset mode button
Stop/Reset Mode
If a digital input configured to panel lock is active, changing module modes will not be possible. Viewing the
instruments and event logs are not affected by panel lock.
STOP/RESET mode is activated by pressing the STOP/ RESET mode button. The STOP/RESET icon is
displayed to indicate STOP/RESET mode operations.
In STOP/RESET mode, the module removes the generator from load (if necessary) before stopping the engine
if it is already running.
If the engine does not stop when requested, the FAIL TO STOP alarm is activated (subject to the setting of the
Fail to Stop timer). To detect the engine at rest the following must occur:
Engine speed is zero as detected by the CANbus ECU. Generator AC Voltage and frequency must be zero.
Engine charge alternator voltage must be zero.Oil pressure sensor must indicate low oil pressure.
When the engine has stopped, it is possible to send configuration files to the module from DSE configuration
suite PC software and to enter the front panel editor to change parameters.
Any latched alarms that have been cleared are reset when STOP/RESET Mode is entered.
The engine is not started, when in STOP/RESET mode. If remote start signals are given, the input is ignored
until AUTO mode is entered.
When left in STOP/RESET mode with no presses of the fascia buttons and configured for `Power Save Mode`,
the module enters Power Save Mode. To `wake' the module, press any fascia control buttons or activate Digital
Input. The same is true for Deep Sleep Mode.
Automatic Mode
If a digital input configured to external panel lock is active, changing module modes is not possible. Viewing
the instruments and event logs are not affected by panel lock.
AUTO mode is activated by pressing the AUTO mode button. The AUTO mode icon is displayed to
indicate AUTO mode operations if no alarms are present. AUTO mode allows the generator to operate fully
automatically, starting and stopping as required with no user intervention.
Waiting In Auto Mode
If a starting request is made, the starting sequence begins. Starting requests can be from the following sources: