– 118 –
<Condensation custom pattern list screen>
1) In the case of setting the number of
stitches
As an example, explanation is given about
the input procedure of condensation custom
number 1 shown in <Fig. 1>.
The number of stitches can be input in
the range from 1 to 100.
Set the number of stitches for step 1 to 3
with numeric keypad
❽
for the number of
stitches and
❾
.
A negative number of stitches can also
be set. In this case, the direction of feed
is reverse direction.
Press
to confirm the setting.
❽
❾
⑤
Conrming the numeric value
Press
to conrm the setting.
<Condensation custom pattern list screen>
<Condensation custom edit screen>
The condensation custom list screen is dis-
played with the condensation custom number
you have created added.
2) In the case of setting the pitch
The pitch can be input in the range from ‒
5
.
00
to
5
.
00
mm.
Set the pitch for step 1 to 1.00 with
for pitch.
Press
to conrm the setting.
3) Carry out the following setting in the similar manner.
For step 2, set the number of stitches to 4, and the pitch to 1.50 mm.
For step 3, set the number of stitches to 3, and the pitch to 1.00 mm.
For step 4, set the number of stitches to 3, and the pitch to ‒1.00 mm.
For step5, set the number of stitches to 2, and the pitch to 1.50 mm.