94 –
Check that the "threshold" you have set is en-
tered. Then, press
again to conrm
the setting. Note that the "threshold" can be
directly entered or corrected on this screen.
The initial value of "threshold" for
the multi-layered section detection
is a rough indication. The threshold
should be nely adjusted accord-
ing to the actual sewing conditions
such as the item to be sewn.
7-5-2. Multi-layered-section detection number of stitches setting function
In the case the multi-layered section detection is enabled, the sewing parameter is automatically returned to
the setting for the normal section of material if the material thickness becomes smaller than the "threshold".
However, the sewing-parameter changeover timing can be changed by setting the multi-layered-section
detection number of stitches. Once the multi-layered-section detection number of stitches is set, the thresh-
old returns to the value for the normal section of material when the aforementioned set number of stitches
is reached after the detection of a multi-layered section of material, even if the sewing is started from the
multi-layered section. It should be noted, however, that the sewing parameter returns to the one for the
normal section of material if the material thickness falls below the "threshold" for the multi-layered section
detection, even within the range of the set multi-layered-section detection number of stitches.
[How to set]
1) Press
on the "Sewing data edit
screen".
The "multi-layered section detection sensor
value screen" is displayed.
2) Enter the number of stitches with numeric
keypad
.
Press
to conrm the setting.
Factory-set value at the time of delivery
: 0
(Number of stitches is not set)
Setting range : 0 to 200
* When the number of stitches is set to zero
(0), the setting of the multi-layered-section
detection number of stitches is rendered
invalid.
<Multi-layered section detection sensor value screen>
<Sewing data edit screen>
<Multi-layered section detection sensor value screen>
After the end of multi-layered sec-
tion of material is fed, the multi-lay-
ered section detection function
detects the at section of material
to return the sewing conditions to
those for the at section. Howev-
er, this reaction sometimes delays
according to the sewing conditions.
If such a delay occurs, it can be
corrected by setting the number of
stitches of the multi-layered section
detection.
After the sewing
machine has
nished sewing
of a multi-
layered section
of material,
the machine's
reaction is also
delayed by a
several number
of stitches.
End of a multi-
layered section
of material
MAX : 3000
MIN : 1000

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JUKI DDL-9000C-F and is the answer not in the manual?

JUKI DDL-9000C-F Specifications

General IconGeneral
BrandJUKI
ModelDDL-9000C-F
CategorySewing Machine
LanguageEnglish

Related product manuals