29
9. PERFORMING RELEASE OF GREASE-UP ERROR
When the number of stitches of grease-up
exceeds 100 million stitches or more, E220,
grease-up warning occurs when turning ON the
power.
Clear the number of stitches of grease-up with
memory switch
, grease-up error clear
after replenishing grease. E220 is displayed each
time turning ON the power until clearing is
performed.
When the number of stitches of grease-up
exceeds 120 million stitches or more, E221,
grease-up error occurs when READY key is
pressed. When E221 occurs, it is not possible to
sew. Clear the number of stitches of grease-up
with memory switch
, grease-up error clear
after replenishing grease
① Display the memory switch data list screen.
Display the memory switch data list screen and
select button (A) of
Grease-up error clear.
The grease-up error clear screen is displayed.
② Clear the number of stitches of grease-up.
When CLEAR button
(B) is pressed, the
pop-up is closed and the number of stitches of
grease-up can be cleared.
A
B