51
-
8-2. List of the memory switch functions
No. Function Setting range
State when
delivered
Remarks
U001
Max. sewing speed
(Speed can be set in a unit of 100 sti/min.)
200 to 2500 2500
U002
Sewing speed of 1st stitch
(Speed can be set in a unit of 100 sti/min.)
200 to 900 200
U003
Sewing speed of 2nd stitch
(Speed can be set in a unit of 100 sti/min.)
200 to 2500 600
U004
Sewing speed of 3rd stitch
(Speed can be set in a unit of 100 sti/min.)
200 to 2500 1000
U005
Sewing speed of 4th stitch
(Speed can be set in a unit of 100 sti/min.)
200 to 2500 2500
U006
Sewing speed of 5th stitch
(Speed can be set in a unit of 100 sti/min.)
200 to 2500 2500
U019
Selection of pedal
: Standard pedal
: AMS 2-pedal unit
: Pedal 1 for standing work (PK51)
: AMS 3-pedal unit (right pedal is given priority)
: AMS 3-pedal unit (left pedal is given priority)
: AMS 3-pedal unit (no priority)
-
U024
Optional pedal 1 operation
: OFF when depressing pedal again
: OFF when detaching from pedal
-
U025
Optional pedal 2 operation
: OFF when depressing pedal again
: OFF when detaching from pedal
-
U030
Selection of base point of pattern enlargement/reduction
: Origin : Sewing start point
- The origin is xed when
using an inversion
pattern.
U031
Sewing machine operation can be stopped with panel key (clear
key)
: Ineffective
: Panel RESET key
: External switch
-
U032
Buzzer sound can be prohibited
: Without buzzer sound : Panel operation sound
: Panel operation sound + error sound
-
Various operations of the sewing machine can be set by programming the memory switch.
The initial setting values at the time of shipment differ with models.