− 8 −
(2) How to use the standard operation panel
1 / switch : Used for determining the contents of setting.
When this switch is pressed, flashing stops and the contents of setting
are determined.
2 / switch : Used for changing the contents of setting.
When this switch is pressed, changeable positions flash on and off.
By pressing the switch, flashing position shifts in the right direction.
3 switch : Used for changing the contents of the selected display (flashing
section).When this switch is pressed, the contents of the display
increase.
4 switch:Used for changing the contents of the selected display (flashing
section).
When this switch is pressed, the contents of the display decrease.
5 PATTERN SELECTION display : The selected pattern is displayed.
6 REVERSE STITCHING : Rendered effective when reverse stitching pattern is selected.
AT START display “ ” Without reverse stitching display / “ ” Reverse stitching display/
“ ” Double reverse stitching display
7 REVERSE STITCHING : Rendered effective when reverse stitching pattern is selected.
AT END display “ ” Without reverse stitching display / “ ” Reverse stitching display/
“ ” Double reverse stitching display
8 NUMBER OF STITCHES display : Number of stitches of reverse stitching or overlapped stitching is
displayed.
9 MATERIAL EDGE SENSOR : Lights up when the material edge sensor setting is selected.
display Function setting No. 2
!0 ONE-SHOT AUTOMATIC : Lights up when the one-shot automatic stitching is selected.
STITCHING display Function setting No. 76
!1 AUTOMATIC : Lights up when the automatic thread trimming by depressing the
THREAD TRIMMING display front part of the pedal is selected.
Function setting No. 3
!2 THREAD TRIMMING : Lights up when the thread trimming prohibition is selected.
PROHIBITION display Function setting No. 9
1
2
4
3
!1
!2
6
7
8
9
!0
5