General data
Menu language EN; DE; FR; IT; ES; PL; NL; PT; CZ; HU; SL; TR; RO
Interfaces 2 x Ethernet, USB, 2x RS485 (1x reserved for string combiner com.), optional
Fault signal relay yes (integrated switch)
DC switch / AC switch no / yes (XL version) / no
Cooling temp. regulated fan, max air throughput 364 m³/h
Number of fans 3x outside, 1x inside
Noise emission <60 db(A)
Housing material AL
H x W x D 28,30 inch x 28,30 inch x 18,11 inch
Weight 172 Ib
Certification Overview: see homepage, download area
4.3 Environmental data
Environmental condi-
tions
Max. installation height 9842 ft (Derating at 6561 ft)
Distance to coastline from
installation
>1640 ft
Ambient temperature of -13 °F - 140 °F
Power derating from > 113 °F
Protection rating (KACO in-
stallation site)
IP66 /NEMA 4X
Relative humidity, non-con-
densing (in operation)
100 %
4.4 Accessories
Accessory articles KACO order no.
KACO blueplanet DC-Breaker 1001860
Bending box 1001917 (absolutely mandatory for UL market!)
Accessory articles KACO order no.
Bending box 1001917
AC inverter input plate kit 1001882 (double row) / 1001906 (M63/32)
AC inverter overvoltage pro-
tection kit
1001884
AC inverter overvoltage pro-
tection kit
1001884
DC inverter overvoltage pro-
tection kit
1001885
LAN inverter overvoltage pro-
tection kit
1001886
RS485 inverter overvoltage
protection kit
1001887
PID connection set 1001888
4 | Technical data Manual
KACO blueplanet 87.0 TL3 KACO blueplanet 92.0 TL3 KACO blueplanet 105 TL3 KACO blueplanet 110 TL3
KACO blueplanet 125 TL3 KACO blueplanet 137 TL3 KACO blueplanet 150 TL3 KACO blueplanet 155 TL3
KACO blueplanet 165 TL3
Page 16
EN-US