KEB COMBIVERT F5-M / S
Name: Basis
12.05.04
Section PageDate
© KEB Antriebstechnik, 2002
All Rights reserved
Chapter
Functional DesriptionOperating and Unit Data
Adr.
min max
default
Adr.
min max
default
0E01h
0,1
A
-
710LTK
6.1.6 Description of In-Parameter
0E00h
In. 0 Inverter type
1
hex
-
FFFFh0h
The inverter type is represented as hexadecimal number. The bits have following significance:
Bit 0-4 Unit size 05, 07, 09 ...
Bit 5 Voltage class 0 = 230 V
1 = 400 V
Bit 6 Phases 0 = 1-phase
1 = 3-phase
Bit 7 free
Bit 8-12 Housing 0 = A 10 = K 20 = U
1 = B 11 = L 21 = V
2 = C 12 = M 22 = W
3 = D 13 = N 23 = X
4 = E 14 = O 24 = Y
5 = F 15 = P 25 = Z
6 = G 16 = Q
7 = H 17 = R
8 = I 18 = S
9 = J 19 = T
Bit 13-15 Control type 0 = G
1 = M
2 = B
3 = S
4 = A
Example:
hex 0 4 0 A
binary 0000010000001010
decimal 0 4 0 0 10
=> 10.F5.G 230V/1ph.
In. 1 Rated inverter current
Display of rated inverter current in A. The value is determined from the power circuit identification (LTK) and cannot be
changed.