6
6
KEB COMBIVERT F5-M / S10
Name: Basis
12.05.04
Chapter Section Page Date
© KEB Antriebstechnik, 2002
All Rights reserved
Functional Desription Motor Data and Controller
dr.0 0600h ✔✔- 0 A 710,0 A 0,1 A LTK*) only F5-M
dr.1 0601h ✔✔- 0 rpm 64000 rpm 1 rpm LTK*) only F5-M
dr.2 0602h ✔✔- 120 V 500 V 1 V LTK*) only F5-M
dr.3 0603h ✔✔- 0,35 kW 400,00 kW 0,01 kW LTK*) only F5-M
dr.4 0604h ✔✔- 0,50 1,00 0,01 LTK*) only F5-M
dr.5 0605h ✔✔- 0,0 Hz 1600,0 Hz 0,1 Hz LTK*) only F5-M
dr.6 0606h ✔✔- 0,000 Ohm 50,000 Ohm 0,001 Ohm LTK*) only F5-M
dr.7 0607h ✔✔- 0,01 mH 500,00 mH 0,01 mH LTK*) only F5-M
dr.14 060Eh - ✔ - 0,01 Nm 10000 Nm 0,01 Nm Motor data only F5-M
dr.15 060Fh - ✔ - 0,01 Nm 10000 Nm 0,01 NmLTK+Mot. data programmable at F5-M
dr.16 0610h ✔✔- 0,01 Nm 10000 Nm 0,01 Nm Adaption only F5-M
dr.17 0611h ✔✔- 1 rpm 32000 rpm 1 rpm Adaption only F5-M
dr.18 0612h ✔✔- 0 rpm 32000 rpm 1 rpm Adaption only F5-M
dr.19 0613h ✔✔- 25 % 250 % 1 % Adaption only F5-M
dr.20 0614h ✔✔- 0,01 2,00 0,01 Adaption only F5-M
dr.21 0615h ✔✔- 0 % 100 % 0,1 % 75 % nur F5-M
dr.23 0617h ✔ - - 0,0 A 710,0 A 0,1 A LTK*) only F5-S
dr.24 0618h ✔ - - 0 rpm 32000 rpm 1 rpm LTK*) only F5-S
dr.25 0619h ✔ - - 0,0 Hz 1600,0 Hz 0,1 Hz LTK*) only F5-S
dr.26 061Ah ✔ - - 0 1000 1 LTK*) only F5-S
dr.27 061Bh ✔ - - 0,1 Nm 6553,5 Nm 0,1 Nm LTK*) only F5-S
dr.28 061Ch ✔ - - 0,0 A 700,0 A 0,1 A LTK*) only F5-S
dr30 061Eh ✔ - - 0,000 Ohm 50,000 Ohm 0,001 Ohm LTK*) only F5-S
dr31 061Fh ✔ - - 0,01 mH 500,00 mH 0,01 mH LTK*) only F5-S
cS.20 0F14h ✔✔- 0,01 Nm 10000 Nm 0,01 Nm -0,01 Nm only F5-M
cS.22 0F16h ✔✔- -0,01 Nm 10000 Nm 0,01 Nm -0,01 Nm only F5-M
Fr.10 090Ah ✔✔✔ 1211
*) dependent on power circuit
Param. Adr.
min
max
default
ENTER
PROG.
R/W
Step
6.6.7 Motor Data Parameter