2.
Select the regeneration disable, press switch F6, and the
regeneration stops.
REMARK
The regeneration performed to protect the system may not
be stopped, but this is not a failure.
PROCEDURE FOR CANCEL OF AFTERTREATMENT DEVICES REGENERATION
DISABLE SETTING
kk
CAUTION
When cancelling the regeneration disable, move the machine to a safe place and check that there is no
person or combustible matter around the machine, and start the cancel operation.
1.
When switch F6 is pressed on the standard screen, “After-
treatment Devices Regeneration” screen is displayed.
(If the screen is not displayed, operate switches F1 and F2
to display “Aftertreatment Devices Regeneration” screen.
2.
Select Cancel of the regeneration disable and press switch
F6, and the regeneration disable is cancelled.
If soot accumulation level (4) is lit 3 or more, the regenera-
tion is started automatically.
REMARK
When cancelling the regeneration disable, set the lock
lever to LOCK position and set the fuel control dial to
Low idle (MIN) position, then cancel the regeneration
disable.
The regeneration disable setting is also cancelled by
turning the starting switch to OFF position to stop the
engine.
EXPLANATION OF COMPONENTS OPERATION
3-122

Table of Contents

Other manuals for Komatsu PC210LC-11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Komatsu PC210LC-11 and is the answer not in the manual?

Komatsu PC210LC-11 Specifications

General IconGeneral
BrandKomatsu
ModelPC210LC-11
CategoryExcavators
LanguageEnglish

Related product manuals