REMARK
• Machines with Automatic Grease System require one
time lubrication each time the bucket is changed. Lu-
bricate at the bucket linkage and at the grease meter-
ing valve as indicated until grease comes out from the
end faces. It will be necessary to replace the plug at
the grease metering valve with a grease nipple during
lubrication. The plug must be replaced after lubrica-
tion.
Grease metering valve for standard machines.
METHOD FOR PARKING MACHINE
WARNING
• Avoid a sudden stop. Stop the machine gradually.
• Place the machine on a firm and level place.
Do not park the machine on a slope.
If it is unavoidably necessary to park the machine on a
slope, block the tracks from movement. As an addi-
tional safety measure, thrust the work equipment into
the ground.
• If the control lever is touched by accident, the machine
may move suddenly, and this may lead to a serious
personal injury or death. Always set the lock lever se-
curely to LOCK position before leaving the operator's
seat.
MACHINE OPERATIONS AND CONTROLS OPERATION
3-210