Omega
15
7.6 Monitoring schedule
For a detailed description of the pump version, components
and accessories supplied by KSB please refer to section 13 of
this operating manual.
Component monitored Action Value required
Mechanical seal
(if applicable)
Check for leakage (daily) see section 8.2 and *
Gland packing
(if applicable)
Check for leakage (daily) 10 to 120 drops / min.
Suction side measuring instrument, ps
(if applicable)
Check pressure (daily) *
Discharge side measuring instrument, pd
(if applicable)
Check pressure (daily) *
Thermometer
(suction / discharge nozzle)
(if applicable)
Check temperature (weekly) *
Flushing line sight glass
(if applicable)
Check flushing water flow
(weekly)
Water flows
Vibration measurement
(if applicable)
Check weekly *
Bearing temperature
(if applicable)
Check weekly Section 7.2
Coupling Check weekly
Annex from p. 47, detailed manufacturer
information
Drive
(if applicable)
See manufacturer’s documentation Ensure contact--free installation
Coupling guard Check monthly No contact permitted
Earthing connection Check monthly Connection must be fitted and marked.
* see list of measuring points (if applicable) in section 13,
Annex.
In the event of deviations proceed as described in the table gi-
ven in section 11.2 (Trouble--shooting).