10: Service Settings
EDS1100/2100 Device Server User Guide 85
Table 10-21 LPD Configuration
5. Click Submit.
6. Repeat above steps as desired, according to additional LPD lines available on your product.
Print Test Page
This selection can be chosen to print a test page.
To print a test page:
1. Select LPD on the menu bar, if you are not already at the LPD web page.
2. Select an LPD line at the top of the page.
3. Select Print Test Page. A popup window appears.
4. Enter the numbers to print in the popup window.
5. Click OK.
LPD Configuration
Settings
Description
Banner Select Enabled to print the banner even if the print job does not specify to do so.
Selected by default.
Binary Select Enabled for the device to pass the entire file to the printer unchanged.
Otherwise, the device passes only valid ASCII and valid control characters to the
printer. Valid control characters include the tab, linefeed, formfeed, backspace, and
newline characters. All others are stripped. Disabled by default.
Start of Job Select Enabled to print a "start of job" string before sending the print data.
End of Job Select Enabled to send an "end of job" string.
Formfeed Select Enabled to force the printer to advance to the next page at the end of each
print job.
Convert Newlines Select Enabled to convert single newlines and carriage returns to DOS-style line
endings.
SOJ String If Start of Job (above) is enabled, enter the string to be sent to the printer at the
beginning of a print job. The limit is 100 characters.
Indicate whether the string is in text or binary format.
EOJ String If End of Job (above) is enabled, enter the string to send at the end of a print job.
The limit is 100 characters. Indicate whether the string is in text or binary format.
Queue Name To change the name of the print queue, enter a new name. The name cannot have
white space in it and is limited to 31 characters. The default is LPDQueueX (for line
number X)

Table of Contents

Other manuals for Lantronix EDS1100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix EDS1100 and is the answer not in the manual?

Lantronix EDS1100 Specifications

General IconGeneral
BrandLantronix
ModelEDS1100
CategoryServer
LanguageEnglish

Related product manuals