EasyManuals Logo
Home>Lenze>Controller>E84AVSC

Lenze E84AVSC User Manual

Lenze E84AVSC
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
8400 StateLine C | Operating instructions
Connection/wiring of the controller
12 L from Firmware V06.00 - DMS 1.1 EN - 11/2011
4 Connection/wiring of the controller
[4-1] Wiring of the power and motor terminals of 230V devices (on the left) and 400V devices (on the right)
[4-2] Wiring of the control terminals / preconfigured assignment (Lenze setting)
J>
PE
Rb1 Rb2
U
V W
X105
T1 T2
X106
"
M
3~
PTC
"
R
b
"
M
3~
"
"
Rb1 Rb2
+
+
+
+
E84AVSCxxxx ...2
1/N/PE AC 230 V
PE
L1
N
PE
F1
K
Z
L1
N
X100
F2
K
K
O
I
R
b
J
+
J>
PE
Rb1 Rb2
U
V W
X105
T1 T2
X106
"
M
3~
PTC
"
R
b
"
M
3~
"
"
Rb1 Rb2
+
+
+
+
E84AVSCxxxx ...4
PE
3/PE AC 400 V/500 V
L1
L2
L3
N
PE
F1…F3
K
Z
L1
+UG
L2
L3
-UG
X100
F4
K
K
O
I
R
b
J
+
X3 - Analog terminals
A1U Main speed setpoint
10 V 100 % reference speed 1500 rpm
(applies to 4-pole asynchronous motors)
O1U Actual speed value
10 V 100 % reference speed 1500 rpm
X4 - Digital terminals
24E External supply - control electronics (optional)
RFR Controller enable / Reset of error message
DI1 Fixed speed setpoint 1 (40 % of the reference speed)
DI2 Fixed speed setpoint 2 (60 % of the reference speed)
DI3 Manual DC-injection braking
DI4 Change of direction of rotation
DO1 Status "Drive is ready"
X101 - relay output
COM/NO Status "Error is pending"
&20
1&
12
$5
$8
$,
*$
28
(
,
5)5
',
',
',
',
'2
*,2
*1'$
9P$
*1',2
;
;
;
9
9
N
9'&
($96&[[[[[

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze E84AVSC and is the answer not in the manual?

Lenze E84AVSC Specifications

General IconGeneral
BrandLenze
ModelE84AVSC
CategoryController
LanguageEnglish

Related product manuals