DC−bus operation
DC−bus variants
Supply with regenerative power supply module
7
l
114
EDS700ACBA EN 5.1
7.3.3 Supply with regenerative power supply module
L2L2
L2.1
L1L1
L1.1
L3L3
L3.1
MMM
33
M
...
~
=
AC
VR1Z1
G1 Gx
AC AC mains
Z1 Regenerative power supply filter
VR1 Regenerative power supply module
G1 ... Gx Controllers
If the regenerative energy produced by a drive system is to be fed back to the AC mains, a
regenerative power supply module of the "Servo Drives 9400" device series can be used. A
brake chopper, to which a brake resistor can be connected, is integrated.
Components to be used
i700 device series Other device series
DC supply
Regenerative power supply modules
− E94ARNE0xx4 + E94AZMR0xx4xDB (13 ... 24 A)
Filter
− assigned to the regenerative power supply module
Interconnected device
Controllers
E70ACM...1... (single axis) −