Technical data
Terminal description
Axis modules
4
l
59
EDS700ACBA EN 5.1
Encoder
X8 Pin
Description
EYF001... cable
1 V
SS
1 V
SS
Hiperface
X8
E70ACM...E
1 A COS
On single axis devices, this
connection is located on the
right−hand side below the labelling
"X8".
2 GND GND
3 B Sin
4 V
CC
V
CC
5 Z +RS485
6
n. c. n. c.
7 −KTY −KTY
8
n. c. n. c.
B
A
X8
9 /A Ref COS
On double axis devices, there are two
of these connections. For the
assignment to the axes, the
designations "A" / "B" are used.
10
n. c. n. c.
11 /B Ref SIN
12
n. c. n. c.
13 /Z −RS485
14 +KTY +KTY
15
n. c. n. c.
i700AX007 a b
" Shield connection at Sub−D housing
Electrical data
General
Cable length (system cable is recommended) Max. 50 m
Encoder types Sin/cos encoder, 1V
SS
Protocols Hiperface®
Number of increments 1 ... 16383
Input frequency max. 250 kHz
VCC
(GND)
Supply voltage 5 V ... 12 V
Current, max.
9 V
250 mA
12 V
+KTY, −KTY Type KTY 83−110

Table of Contents

Other manuals for Lenze i700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i700 Series and is the answer not in the manual?

Lenze i700 Series Specifications

General IconGeneral
Product CategoryInverter
Seriesi700
Protection ClassIP20
Frequency Range0 to 599 Hz
Control TypeVector control
Communication InterfacesEtherCAT, CANopen
SafetySTO (Safe Torque Off), SS1 (Safe Stop 1)
Overload Capacity200% for 3 seconds
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Overtemperature
Ambient Temperature-10°C to +50°C
Voltage400 V
Input Voltage3-phase AC