WARNING: Remove AC when adding or removing any jumper, plug or resistor.
Power Supply Static Test (Forcing on the SMPS in stages)Power Supply Static Test (Forcing on the SMPS in stages)
TEST CONDITIONS:
Connector going to the Y-SUS P811 is disconnected.
P500 on the Main board disconnected (coming in on P813).
Use the holes on the connector P500 (Main Board side) to insert the
resistors and jumper lead.
Connect (2) 100 Watt light bulbs in series between VS and Ground
.
When the supply is operational in its normal state the Auto Ground line at Pin
18 of P813 is held at ground by the Main Board.
This Power Supply can be powered on sequentially to test the Controller
Chip IC701 operational capabilities and for troubleshooting purposes.
i 18 i d T t th SMPS t th l
y
sconnec
ng
, p
n
s opene
.
o re
urn
e
o
e norma
state for this test procedure, this pin must be grounded.
(See first step A below).
Note: Leave previous installed 100Ω resistor in place
when adding the next resistor.
(A) Ground the Auto Gnd Line (Pin 18) will allow the supply to be
powered up one section at a time.
(B) Add a 100Ω ¼ watt resistor from 5V Standby to RL_ON and the 17V
and 5V Run Lines on P813 will become active Also AC
.
.
and Error_Det (4.1V) become active (Not Used).
(C) Add a 100Ω ¼ watt resistor from any 5V line to M_ON to make the
(Monitor) M5V, VS and VA lines operational.
(VS pins 1 and 2) and (VA pins
May 2011 50PV450 Plasma
52
.
P811 (M5V pin 7)