6.5.1. Changing emulated EDID
Step 1. Choose the desired EDID list on the source panel and select an EDID.
Step 2. Press the Emulated button on the top of the Destination panel.
Step 3. Select the desired port on the right panel (one or more ports can be selected); the
EDID(s) will be highlighted with a yellow cursor.
Step 4. Press the Transfer button to change the emulated EDID.
6.5.2. Learning an EDID
The process is the same as changing the emulated EDID; the only difference is the
Destination panel: press the User button. Thus, one or more EDIDs can be copied into the
user memory either from the factory memory or from a connected sink (Dynamic).
6.5.3. Exporting an EDID
ATTENTION!
This function is working on Windows and Mac OS X operating systems and under Firefox
or Chrome web browsers only.
Source EDID can be downloaded as a le (*.bin, *.dat or *.edid) to the computer.
Step 1. Select the desired EDID from the Source panel (highlighted with a yellow cursor).
Step 2. Press the Export button to open the dialog box and save the le to the computer.
6.5.4. Importing an EDID
Previously saved EDID (*.bin, *.dat or *.edid le) can be uploaded to the user memory:
Step 1. Press the User button on the top of the Source panel and select a memory slot.
Step 2. Press the Upload button below the Source panel.
Step 3. Browse the le in the opening window then press the Open button. Browsed EDID is
imported into the selected User memory.
ATTENTION!
The imported EDID overwrites the selected memory place even if it is not empty.
6.5.5. Deleting EDID(s)
The EDID(s) from User memory can be deleted as follows:
Step 1. Press User button on the top of the Destination panel.
Step 2. Select the desired memory slot(s); one or more can be selected (“Select All” and
“Select None” buttons can be used). The EDID(s) will be highlighted with a yellow
cursor.
Step 3. Press the Clear selected button to delete the EDID(s).