6.6.3. Ethernet tab (in case of SW4-OPT-TX240RAK model only)
Basic information is shown about the network communication; the port name can be
changed and Ethernet port can be enabled/disabled.
6.7. Event Manager
The feature means that the device can sense changes on its ports and able to react
according to the pre-dened settings. The development idea of the Event manager is
based on users’ feedbacks. In many cases internal events (such as signal present or HDCP
active) are necessary to display but it is not easy when the device is hard to access (e.g.
built under the desk).
The Event manager can be congured to perform an action if a condition has been detected.
E.g. the desired setup is that after a certain type of signal has been detected on I1 port, the
port has to be switched to O1. The settings can be done via the LDC in the Control/Events
tab, or by LW3 protocol commands. 20 events can be congured; 10 events are listed at
the same time.
Numerous new ideas and requests have been received in connection with the features
and settings of the Event manager since the rst release. Therefore, the user interface has
been re-designed and many new functions implemented. The Event editor can be opened
by pressing the Edit button at each Event.
There is a gray bar on the left of the Event panel in each line. If a condition and an action are
set and the Event is enabled, the bar is displayed in green.
Control menu, Event Manager tab
Page 40 / 106 Software control