LOMBARDINI Engines are built to supply their performances in a safe and long-lasting way.
To obtain these results, it is essential for users to comply with the servicing instructions given in the relative manual along with
the safety recommendations listed below.
The engine has been made according to a machine manufacturer's specifications and all actions required to meet the essential
safety and health safeguarding requisites have been taken, as prescribed by the current laws in merit.
All uses of the engine beyond those specifically established cannot therefore be considered as conforming to the use defined
by LOMBARDINI which thus declines all liability for any accidents deriving from such operations.
The following indications are dedicated to the user of the machine in order to reduce or eliminate risks concerning engine
operation in particular, along with the relative routine maintenance work.
The user must read these instructions carefully and become familiar with the operations described.
Failure to do this could lead to serious danger for his personal safety and health and that of any persons who may be in the
vicinity of the machine.
The engine may only be used or assembled on a machine by technicians who are adequately trained about its operation and
the deriving dangers.
This condition is also essential when it comes to routine and, above all, extraordinary maintenance operations which, in the
latter case, must only be carried out by persons specifically trained by LOMBARDINI and who work in compliance with the
existing documentation.
Variations to the functional parameters of the engine, adjustments to the fuel flow rate and rotation speed, removal of seals,
demounting and refitting of parts not described in the operation and maintenance manual by unauthorized personnel shall
relieve LOMBARDINI from all and every liability for deriving accidents or for failure to comply with the laws in merit.
On starting, make sure that the engine is as horizontal as possible, unless the machine specifications differ.
In the case of manual start-ups, make sure that the relative actions can take place without the risk of hitting walls or dangerous
objects, also considering the movements made by the operator.
Pull-starting with a free cord (thus excluding self-winding starting only), is not permitted even in an emergency.
Make sure that the machine is stable to prevent the risk of overturning.
Become familiar with how to adjust the rotation speed and stop the engine.
Never start the engine in a closed place or where there is insufficient ventilation.
Combustion creates carbon monoxide, an odourless and highly poisonous gas.
Lengthy stays in places where the engine freely exhausts this gas can lead to unconsciousness and death.
The engine must not operate in places containing inflammable materials, in explosive atmospheres, where there is dust that
can easily catch fire unles specific, adequate and clearly indicated precautions have been taken and have been certified for
the machine.
To prevent fire hazards, always keep the machine at least one meter from buildings or from other machinery.
Children and animals must be kept at a due distance from operating machines in order to prevent hazards deriving from
their operation.
Fuel is inflammable.
The tank must only be filled when the engine is off.
Thoroughly dry any spilt fuel and move the fuel container away along with any rags soaked in fuel or oil.
Make sure that no soundproofing panels made of porous material are soaked in fuel or oil.
Make sure that the ground or floor on which the machine is standing has not soaked up any fuel or oil.
Fully tighten the tank plug each time after refuelling.
Do not fill the tank right to the top but leave an adequate space for the fuel to expand.
Fuel vapour is highly toxic.
Only refuel outdoors or in a well ventilated place.
Do not smoke or use naked flames when refuelling.
The engine must be started in compliance with the specific instructions in the operation manual of the engine and/or
machine itself.
Do not use auxiliary starting aids that were not installed on the original machine (e.g. Startpilot’).
Before starting, remove any tools that were used to service the engine and/or machine.
Make sure that all guards have been refitted.
General remarks and safety information
- Important remarks and features of the text are highlighted
using symbols, which are explained below:
Danger Attention
This indicates situations of grave danger which, if ignored,
may seriously threaten the health and safety of individuals.
SAFETY AND WARNING DECALS
Caution Warning
This indicates that it is necessary to take proper precautions
to prevent any risk to the health and safety of individuals
and avoid financial damage.
Important
This indicates particularly important technical information
that should not be ignored.
SAFETY REGULATIONS

Table of Contents

Other manuals for Lombardini LDW 502

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lombardini LDW 502 and is the answer not in the manual?

Lombardini LDW 502 Specifications

General IconGeneral
Engine TypeDiesel, 4-stroke
Number of Cylinders2
Fuel SystemIndirect injection
Starting SystemElectric start
Lubrication SystemForced lubrication with gear pump
Bore x Stroke72 mm x 62 mm
Cooling SystemAir-cooled
Displacement505 cm³ (30.8 cu in)