19.1. TROUBLE SHOOTING CABLES AND SINGLE LEVER CONTROLLER
PROBLEM POSSIBLE CAUSE CORRECTION
Single handle controller will not
operate all valve functions.
Cable not adjusted properly. With single lever controller handle
lock disengaged, readjust cable for
correct valve operation.
Check for damage to single lever
controller or cable.
Replace damaged part and readjust
cables.
Single lever controller hard to
operate.
Cables contaminated. Remove cables. Replace or clean
cables.
Single Handle Controller will not
operate valve correctly.
Cables not connected to proper
spools.
Check cable routing from valve to
single handle controller.
Single handle controller not rotated
correctly.
Check location of single handle
controller main pivot. If not
positioned correctly disassemble
and correct.