Swing-away lattice
3.4 Description of the rigging work
Lattice extension operating instructions 3 112 441 en 3 - 45
GMK 4100/4100-L/5095
11.01.2008
Undoing the connection – with 17 m (56 ft) swing-away lattice
• Before undoing the connection, check whether:
– The connection in the
Front area has been established; à p. 3 - 38
– The connection at the pivot point between section 2 and section 1 has
been established;
à p. 3 - 48
• Pull the pin (2) out of the connecting point (3).
• Insert the pin in the holder (1).
• Secure the pin with the retaining pin.
Undoing the connection – when removing section 2
• Check whether section 2 is slung at the centre of gravity; à p. 2 - 5.
s
G
Risk of accidents due to falling parts
Before undoing the connection, make sure all of the aforementioned con-
nections have been established.
In this way you will prevent either section 2 or section 1 or both of them
from falling down when the connection is undone.