Swing-away lattice
3.4 Description of the rigging work
3 - 70 3 112 441 en Lattice extension operating instructions
GMK 4100/4100-L/5095
11.01.2008
At the 17 m (56 ft)
swing-away lattice
Connecting the lifting limit switch
• Fit the lifting limit switch (3) onto the clamp
(2) and secure it with a retaining pin.
• Lay the connecting cable (4) in such a way
that it will not be damaged during crane
operation, and insert the lifting limit switch
into the socket (1).
For operation with the 17 m (56 ft) swing-away
lattice, the connection for the lifting limit
switch at the 10 m (33 ft) swing-away lattice
must be overridden with the short-circuit plug.
Removing the lifting limit switch
• Pull the plug from the socket (1).
• Remove the lifting limit switch (3) from the
clamp (2).
• Attach the retaining pin to the lifting limit
switch.