Programme chart
165
Additional programmes
Programme Application
Special 93°C-10' Programme for cleaning and thermal disinfection at 93°C with 10
minutes’ temperature holding time.
The wash water is not pumped away until after disinfection is
complete.
Drain To drain away wash water, e.g. after a programme has been
cancelled (see “Operation/Cancelling a programme”).
Rinsing Programme for rinsing the wash cabinet, for flushing out saline
solution (see “Water softener/Adding salt”) or for rinsing heavily
soiled load items, e.g. for pre-rinsing soiling, residual disinfecting
agent or to prevent items drying out and to prevent incrustation
before running a full load. Cold water is used for rinsing, holding
time: 1Min
Demineralised rinse Programme for rinsing the wash cabinet and for rinsing load items
with demineralised water (DI water), holding time: 3Min.
Programme selection depending on the accessories used
Upper basket Lower basket Water volume Programme
Carrier
with spray arm
for various inserts
2injector
modules
Carrier
for various inserts
2injector
modules
Universal
Standard
Intensive
Inorganic
Organic
Plastics
Mini
Oil programme
+2.0 to 2.5l
Injector plus
A 303
(+1module)
Pipettes