Problem solving guide
63
Cleaning the drain filter
Once the flow of water ceases:
Remove the drain filter completely.
Clean the drain filter thoroughly.
Check the drain pump impellers to
make sure they can rotate freely.
Remove any foreign objects (e.g.
buttons, coins, etc.) and clean the
interior.
Put the drain filter back in place and
secure it.
Risk of damage from leaking
water.
Water will escape from the machine
if you forget to replace the drain filter.
Replace the drain filter correctly and
tighten it securely.
Opening the door
Danger of injury due to rotating
drum.
Reaching into a rotating drum is
extremely dangerous and may result
in injury.
Always make sure that the drum is
stationary before reaching in to
remove laundry.
Use a screwdriver to unlock the door.
Pull open the door.