Pellerin Milnor Corporation 25
External Fault Error — This message is triggered by a device external to the MilTouch™ ma-
chine. This error usually originates with the chemical supply system.
Loadcell Comm Failure — This error can occur on machines with the optional weighing sys-
tem (load cells). The controller issues this error when it cannot receive data, or receives an unex-
pected data stream from the load cell controller.
Level Too Low — After the machine fills to the configured minimum (low) water level, the
controller turns off all outputs and signals this error if the water level drops below half of the min-
imum water level and remains below half of the minimum water level for 30 continuous seconds.
4.2.2 Error Correction
BNCLJT05.C01 0000304574 A.10 B.14 A.9 9/11/20 3:52 PM Released
Touch (in the error code dialog box, Figure 23: Sample Error Code Dialog Box, page 22 )
to view the Error Causes/Solutions display (shown in the following figure).
The Error Causes/Solutions display gives a list of possible causes for the error. Touch one of
the error causes in the list for an explanation of how to correct it.
Some errors do not have additional details on how to solve them.
Troubleshooting