10. PROGRAMMING
10 - 5
10.3 Program Example when QCPU (Q mode) is Used
The network parameter and the automatic refresh parameter are set by the GX
Developer.
(1) Parameter settings
(a) Network parameter settings
(b) Automatic refresh parameter settings
POINT
The remote device station initialization step registration function cannot be
used.
When the remote device station initialization step registration instruction
(SB000D) is turned OFF after initialization processing, the remote register value
set in the initialization step registration is cleared. Set the pulse input
mode/function selection register/external output hold-clear in the sequence
program.
For program examples in this chapter, the pulse input mode/function selection
register/external output hold-clear are set in the sequence program.