Simrad GB40 / Northstar 8000i radar setup
To set antenna height
Select Pages (Display 8000i) > Setup > Radar.
Press edit and key in the height of the scanner above sea level in feet or meters
depending on system units setting.
Select Return.
To Transmit
From the radar page select Radar Mode.
Select Transmit.
To change the radar bearing alignment:
Select Pages (Display 8000i). If you:
-
don't have a page that shows the Radar screen in one window and the Chart screen in
the other window, edit or create a page that shows these two windows.
-
do have a page that shows the Radar screen in one window and the Chart screen in
the other, select it.
Check that the Chart has the Radar Overlay turned On.
Select the Radar window so that it becomes active. If you can't see the Adjust Radar
button, select Return.
Select Adjust Radar, then select Installation.
The Bearing Alignment button shows the current setting. Select it to change the setting.
Use the Up and Down buttons to move the radar image one degree at a time, until the
radar overlay is aligned with the chart.
Select OK.
Select Return.
Accurate heading data is required
Your display may need a software upgrade to get full functionality of the Broadband radar.
Please contact your dealer for further information.