5-22
f. Upon normal completion, a screen display is presented "OK".
g. A power-supply switch is switched off -> turned on, A signal generator (There is no designation in the
input signal.) and a writing equipment are connected with the D-SUB signal cable directly.
h. Display “INFORMATION” of the OSD, and confirm that the model name (LCD1920NX) and serial
number have been correctly written.
3.4 EDID data file
The EDID data file text is shown below. When you write or inspect EDID for this monitor, the following table can
be used.
file name : EDID-208.TXT
EDID-208 (Analog)
0 1 2 3 4 5 6 7 8 9 A B C D E F
00
00 FF FF FF FF FF FF 00 38 A3 DE 65 01 01 01 01
10
10
*1)
0C
*2)
01 03 0E 26 1E 8C EA 2C 95 A6 58 4A 9A 26
20
21 50 54 BF EF 80 71 4F 81 80 01 01 01 01 01 01
30
01 01 01 01 01 01 30 2A 00 98 51 00 2A 40 30 70
40
13 00 78 2D 11 00 00 1E 00 00 00 FD 00 32 4B 1E
50
52 0E 00 0A 20 20 20 20 20 20 00 00 00 FC 00 4E
60
45 43 20 4C 43 44 31 39 32 30 4E 58 00 00 00 FF
70
00 32
*3)
34 30 30 30 30 31 51 41 0A 20 20 20 00 F4
*4)
Table 1 Data list (Management number : EDID-208)
file name : EDID-209.TXT
EDID-209 (Digital)
0 1 2 3 4 5 6 7 8 9 A B C D E F
00
00 FF FF FF FF FF FF 00 38 A3 DE 65 01 01 01 01
10
10
*1)
0C
*2)
01 03 80 26 1E 8C EA 2C 95 A6 58 4A 9A 26
20
21 50 54 BF EF 80 71 4F 81 80 01 01 01 01 01 01
30
01 01 01 01 01 01 30 2A 00 98 51 00 2A 40 30 70
40
13 00 78 2D 11 00 00 1E 00 00 00 FD 00 32 4B 1E
50
52 0E 00 0A 20 20 20 20 20 20 00 00 00 FC 00 4E
60
45 43 20 4C 43 44 31 39 32 30 4E 58 00 00 00 FF
70
00 32
*3)
34 30 30 30 30 31 51 41 0A 20 20 20 00 82
*4)
Table 2 Data list (Management number : EDID-209)
Note 1: address 10h Week of manufacture = Month of manufacture × 4
Note 2: address 11h Year of manufacture - 1990
Note 3: address 71h ~ 7Dh Serial Number (ASCII coded)
If less than 13 char, terminate with 0Ah and fill the rests with 20h.
Note 4: address 7Fh Checksum
The sum of entire 128 byte shall be equal to 00h.