Ventilation
F
ilter settings
The filter alarm is from the factory set using a timer default set at 90 days between filter changes. This
interval can be changed and adapted to meet local requirements, or where a pollenfilter is installed, for
example, which is replaced at longer intervals.
It is also possible to deselect the filter alarm. This is usually done in apartment buildings where the
caretaker changes the filters according to a schedule and does not want the residents calling when
there is a filter alarm if he is a day late.
Settings for supply air filters and extract air filters are set separately. The unit leaves the factory with
a plate filter as standard, but an pollen filter can be purchased for the outdoor air. The service lives of
the two types of filters differ.
Ventilation
Filter settings
Set ventilation to standby Settings:
Standard setting:
Description:
On / Off
Off
Before opening the unit to change the filter, turn off
the ventilation.
NB: When the standby function is de-activated, the
ventilation starts following a delay of about 5 minutes
delay.
NB: If you forget to turn on the ventilation again, it will
automatically restart after 2 hours.
Outdoor air filter
Filter change warning Settings:
Standard setting:
Description:
Timer / None
Timer
Timer: Counts the days to the next replacement.
None: No warning is shown when the filter needs
changing.
Days between filter change Settings:
Standard setting:
Description:
30 180 days
90 days
Number of days between filter changes can be set as
required.
It is important that filters are clean in order to give
optimum operation of the unit and low power
consumption. Dirty filters reduce the production of
domestic hot water.
Days to next filter change Description: Shows how many days remain until the next filter
change.
Reset timer Description: Press to reset timer.
NB: This has to be done after each filter change.
Extract air filter Same settings options as
for the outdoor air filter
Compact P / Compact P Polar (English)
BY NILAN
13

Other manuals for nilan Compact P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the nilan Compact P and is the answer not in the manual?

nilan Compact P Specifications

General IconGeneral
Brandnilan
ModelCompact P
CategoryHeat Pump
LanguageEnglish

Related product manuals